AU Netzteil mit 2x2 Terminal Block, 18W€14.50excl. VATRRP €15.718%
Teltonika

Teltonika AU Netzteil mit 2x2 Terminal Block, 18W

SKU: pr3pxau3|Unavailable

The Teltonika AU Netzteil mit 2x2 Terminal Block is an 18W AC-DC power supply designed for Australian (Type I) mains outlets, delivering a regulated 12 VDC output at up to 1.5 A via a secure 4-pin, 3 mm pitch terminal block connector. It ensures stable power for compatible equipment with integrated short-circuit and fuse input protection.

Input Voltage Range
100–240 VAC (absolute maximum 90–264 VAC)
Input Frequency
50/60 Hz (47–63 Hz absolute maximum)
Inrush Current
40 A max
Overshoot
≤10%

€14.50excl. VATRRP €15.718%

Description

Highlights at a Glance

  • Input Voltage Range: 100–240 VAC (absolute maximum 90–264 VAC)
  • Input Frequency: 50/60 Hz (47–63 Hz absolute maximum)
  • Inrush Current: 40 A max
  • Overshoot: ≤10%
  • HIPOT (Dielectric Withstand): AC3000V primary to secondary
  • MTBF: 50,000 hours
  • Certifications: AS/NZS60950.1:2011, IEC 62321 series

Electrical Characteristics

The power supply operates from a universal AC input of 100–240 VAC, with an absolute maximum range of 90–264 VAC, and accepts line frequencies of 50/60 Hz (47–63 Hz absolute maximum). It draws 0.6 A at nominal input and withstands inrush currents up to 40 A. The output voltage is tightly regulated within an absolute range of 11.40–12.60 VDC, and overshoot is limited to 10% under dynamic load conditions.

Protection and Reliability

Designed for continuous operation, the unit undergoes a dielectric withstand test (HIPOT) of AC3000V between primary and secondary, ensuring robust isolation. It is rated for a mean time between failures (MTBF) of 50,000 hours, reflecting high reliability in demanding environments.

Physical Design

The compact form factor measures 46.5 x 60 x 93.5 mm and weighs 2000 g. It features an Australian (Type I) mains plug for direct connection to local outlets, simplifying deployment in AU regions.

Compliance & Certifications

The power supply is certified to AS/NZS60950.1:2011 for safety, and complies with IEC 62321 series standards for hazardous substances, including IEC 62321-7-1:2015, IEC 62321-6:2015, IEC 62321-5:2013, IEC 62321-4:2013, and IEC 62321:2008 Annex C.

Downloads